AECOM
Principal Mechanical Engineer (CFD) - Data Centers
Job description
AECOM is seeking a hands-on CFD Engineer to join its Data Center team. This individual-contributor role is responsible for executing internal and external airflow, thermal, and equipment-discharge studies with minimal oversight. The successful candidate will convert complex simulation results into practical design actions, clearly communicate assumptions and limitations, and help establish repeatable, high-quality CFD workflows across multiple concurrent projects.
Own the full CFD study lifecycle: clarify the design question, define scope and acceptance criteria, develop the methodology, build geometry, generate the mesh, establish boundary conditions, solve, verify convergence, post-process results, and issue technical reports.
Perform internal data hall studies addressing rack inlet temperatures, airflow distribution, hot- and cold-aisle containment, bypass and recirculation, raised-floor or slab configurations, cooling-unit placement, rack density, failure modes, and capacity-expansion scenarios.
Perform external studies for cooling towers, chillers, dry coolers, generator and boiler exhaust, mechanical yards, relief air, outdoor-air intakes, heat rejection, plume behavior, short-circuiting, and thermal re-entrainment.
Conduct steady-state and transient analyses for cooling-system outages, equipment failures, load changes, control sequences, thermal ride-through, and other operating scenarios defined by the project team.
Develop defensible modeling assumptions using design documents, equipment data, controls narratives, weather data, commissioning information, and field measurements; identify data gaps and document their impact on conclusions.
Apply sound verification and validation practices, including mesh-sensitivity checks, mass and energy balance reviews, convergence assessment, comparison with hand calculations, and correlation to measured or monitoring data when available.
Evaluate results against project-specific criteria and relevant guidance, including ASHRAE TC 9.9 thermal guidance and applicable client, code, and industry requirements.
Translate findings into prioritized, actionable recommendations for equipment selection, airflow management, containment, intake/exhaust separation, controls, phasing, redundancy, and operational resilience.
Prepare concise, client-ready reports and visualizations that clearly communicate methodology, assumptions, scenarios, results, risks, limitations, and recommended next steps.
Present findings and coordinate directly with multidisciplinary project teams to resolve issues and confirm implementation of recommendations.
Contribute to standardized templates, modeling procedures, quality-control checklists, libraries, and lessons learned; support technical knowledge sharing and mentoring of less-experienced staff.