Compa
Engineer 2
Job description
Electrical Engineer 2 – Plutonium Rapid Response Team
COMPA Industries is searching for qualified candidates for Electrical Engineer 2 and Electrical Engineer 3 positions supporting Los Alamos National Laboratory (LANL) in Los Alamos, NM.
Salary: $65/hr – $70/hr, depending on experience
Location: 100% Onsite – Los Alamos, NM
Citizenship: U.S. Citizenship Required
Clearance: Ability to obtain and maintain a DOE Q Clearance
Work Schedule: 4/10s, day shift; schedules may include Monday–Thursday, Thursday–Sunday, or Friday–Monday
Assignment Duration: 1 year, with possible extension up to 3 years
Extension/Conversion: Yes, conversion is possible
Positions Available: 1 Engineer 2 and 1 Engineer 3
Start Date: ASAP
Travel: No travel expected
Per Diem/Relocation: Per diem available; no relocation
Remote/Hybrid: No – 100% onsite
🚫 Mandatory Experience Requirement – Read Before Applying
Applicants must have a Bachelor’s Degree in Electrical Engineering from an ABET-accredited institution and direct electrical design engineering experience supporting facility design, operations, maintenance, construction, or project engineering activities.
Candidates must be able to produce, review, and interpret electrical design documentation and construction documents in a field-facing engineering environment.
Candidates without the following experience will not be considered:
Bachelor’s Degree in Electrical Engineering from an ABET-accredited institution
U.S. Citizenship and ability to obtain and maintain a DOE Q Clearance
Ability to work 100% onsite in Los Alamos, NM
Electrical design experience related to facility power systems
Experience producing and interpreting electrical construction documents, drawings, and specifications
Ability to support field/construction questions, field changes, and design interpretation
Impact
Electrical Engineers supporting the Plutonium Rapid Response Team provide design engineering support for facility design, operations, maintenance, construction, and field execution activities. This role directly supports TA-55 and related plutonium facility mission areas by ensuring electrical designs, construction documents, and field engineering solutions are safe, technically accurate, constructible, and aligned with LANL and DOE/NNSA requirements.
The selected engineers will support rapid-response design needs, review LAP-4 and internal designs, evaluate requested field or personnel changes, and help resolve field issues impacting construction, maintenance, and facility operations.
Responsibilities
Perform electrical engineering design, analysis, calculations, and design reviews.
Develop, review, interpret, and support electrical engineering design packages.
Produce and review construction documents, drawings, specifications, calculations, markups, and technical deliverables.
Support facility design, operations, maintenance, construction, modifications, and project execution.
Review LAP-4 designs and internal design packages.
Support field engineering questions, construction documentation, design interpretation, and field issue mitigation.
Provide engineering input for low-voltage facility power systems, including common 120V, 208V, and below-480V applications.
Support conductor sizing, conduit sizing, junction box layouts, electrical routing, equipment installation, and construction-ready design documentation.
Coordinate across engineering, construction, operations, maintenance, work control, project management, and facility organizations.
Apply applicable electrical engineering codes, standards, procedures, and DOE/NNSA requirements.
Use engineering technology, drafting tools, and markup software to support design development and review.
Work independently and collaboratively as part of a multi-discipline engineering team.
Continuously improve engineering work processes to meet customer and mission needs.
For Engineer 3 candidates, provide technical direction, support junior personnel, lead assigned activities, and coordinate more complex engineering deliverables.
Minimum Qualifications
Engineer 2:
Bachelor’s Degree in Electrical Engineering from an ABET-accredited college or university.
Minimum 3 years of relevant electrical engineering experience.
Strong experience producing, reviewing, and interpreting electrical design documents.
Experience supporting construction documents, specifications, and field-facing design support.
Engineer 3:
Bachelor’s Degree in Electrical Engineering from an ABET-accredited college or university.
Strong electrical engineering experience, ideally 6+ years of relevant experience.
Advanced ability to produce, review, and interpret electrical construction documents, drawings, specifications, and design packages.
Ability to support more complex design, field engineering, construction, and interdisciplinary coordination activities.
Minimum Qualifications for Both Levels:
Working knowledge of industry, regulatory, and DOE/NNSA codes, standards, and criteria relevant to electrical engineering.
Knowledge of commonly applied codes and standards at DOE and DOD facilities, including NQA-1, IBC, NFPA, and NEC.
Prior experience facilitating, developing, reviewing, or supporting engineering design packages.
Familiarity with typical engineering deliverables, including construction documents.
Experience with computer-aided design/drafting software or markup tools.
Ability to work independently and collaboratively as part of a multi-discipline technical team.
Ability to access plant/facility areas and walk around field locations as needed.
Ability to obtain and maintain a DOE Q Clearance.
Ability to obtain required LANL access, including green strap and A-Level access.
U.S. Citizenship required.
Preferred Qualifications
Experience supporting DOE, NNSA, DOD, LANL, nuclear, high-hazard, or mission-critical facilities.
Previous experience supporting TA-55, plutonium facilities, RLUOB, or related nuclear facility environments.
Experience with facility electrical design, low-voltage power distribution, 120V/208V systems, below-480V applications, panels, feeders, conductors, conduit, junction boxes, grounding, lighting, controls, instrumentation, one-lines, schematics, and equipment installation support.
Experience creating construction documents and technical specifications.
Experience reading and interpreting existing facility drawings and internal design packages.
Experience mitigating field issues and supporting construction or maintenance execution.
Experience supporting operations, maintenance, facility modifications, or rapid-response engineering requests.
Experience with AutoCAD, Revit, Bluebeam, BIM, or other design/markup tools.
Control system experience is useful but not required.
Familiarity with LANL engineering processes, procedures, standards, and guides.
Knowledge of DOE Order 426.2 or nuclear facility personnel qualification requirements.
Current EIT or PE registration is a plus.
Core Skills
Electrical design engineering
Low-voltage facility power design
120V, 208V, and below-480V electrical systems
Conductor sizing
Conduit sizing
Junction box design/layout
Construction document development
Electrical drawing and specification review
Design package development and interpretation
Field engineering support
Construction support and field issue mitigation
Electrical calculations and analysis
NFPA and NEC application
NQA-1 awareness
DOE/NNSA code and standards compliance
Multi-discipline coordination
Technical documentation and markup tools
Problem solving in a fast-paced engineering environment
Strong written and verbal communication
Independent and team-based work execution
Work Schedule
This position is full-time onsite and may require a 4/10 day-shift schedule. Schedules may include Monday–Thursday, Thursday–Sunday, or Friday–Monday, depending on operational needs.
A training period may follow a Tuesday–Friday, 10-hour shift schedule. After training, employees may be assigned to Friday–Monday, 10-hour shifts or another 4/10 day-shift schedule based on management direction.
Work Environment
This position is 100% onsite in Los Alamos, NM. The selected candidate will primarily work at TA-35 behind the fence while supporting TA-55 as the primary client, along with downstream was